ABB
1SDA074784R1XT2S 125 TMA 80-400..800 4p F F UL/CSA (XT2SU4080BFF000XXX)
XT2S 125 TMA 80-400..800 4p F F UL/CSA (XT2SU4080BFF000XXX)
Moulded / Molded Case Circuit Breaker (MCCB) - UL 80% rated version - ABB / SACE (Tmax XT (UL/CSA) series) - XT2S 125 TMA 80-400..800 4p F F UL/CSA - 4-poles (4P4d) - Rated current 80A - Short circuit rating 35kA (480Vac; UL489) - Thermal-Magnetic (adjustable) (TMA) trip unit - equivalent to XT2SU4080BFF000XXX / XT2S125TMA804008004pFFULCSA
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
1SDA074784R1
Online Price
$3,285.48
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
1SDA074784R1ABB - Tmax XT UL/CSA
Description
Moulded / Molded Case Circuit Breaker (MCCB) - UL 80% rated version - ABB / SACE (Tmax XT (UL/CSA) series) - XT2S 125 TMA 80-400..800 4p F F UL/CSA - 4-poles (4P4d) - Rated current 80A - Short circuit rating 35kA (480Vac; UL489) - Thermal-Magnetic (adjustable) (TMA) trip unit - equivalent to XT2SU4080BFF000XXX / XT2S125TMA804008004pFFULCSA
Specifications
Primary brand
ABB
Secondary brand
SACE
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
Tmax XT (UL/CSA)
Sub-range name
XT2S complete breakers
Functions
Moulded / Molded Case Circuit Breaker (MCCB)
Design
UL 80% rated version
Poles
4-poles (4P4d)
Rated current
80A
Trip current rating
80 AT
Frame current rating
125 AF
Rated Voltage (DC)
500Vdc
Rated voltage (AC)
600Vac
Rated impulse voltage (Uimp)
8 kV
Connection type
Ring-lug or bar connections
Short circuit breaking rating
100kA (240Vac; UL489)
35kA (480Vac; UL489)
22kA (600Vac; UL489)
35kA (480Vac; UL489)
22kA (600Vac; UL489)
Trip unit type
Technology = Thermal-Magnetic (adjustable)
Series = TMA
Display = none
Series = TMA
Display = none
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Magnetic protection (Short-circuit)
Protection settings
Over-current -- adjustable 0.7...1 x In (56A...80A)
Short-circuit pickup current -- adjustable 5...10 x In (400A...800A)
Short-circuit pickup current -- adjustable 5...10 x In (400A...800A)
Operating mode
Toggle
Dimensions
H130mm x W120mm x D82.5mm
Mechanical durability (at no load)
25000 operations
Order code / Manufacturer SKU
XT2S 125 TMA 80-400..800 4p F F UL/CSA
XT2SU4080BFF000XXX
XT2SU4080BFF000XXX
Manufacturer product status
Commercialized
Equivalent to
XT2SU4080BFF000XXX
XT2S125TMA804008004pFFULCSA
XT2S125TMA804008004pFFULCSA
EAN code
8015644787615
UPC code
888614404243
UNSPSC code
39121616
Compliant with standard(s)
UL 489
CSA C22.2
EC directive "Low Voltage Directive" (LVD) no. 2014/35/EC
EC directive "Electromagnetic Compatibility Directive" (EMC) 2014/30/EC
Lloyd's Register of Shipping (LR)
Germanischer Lloyd (GL)
Bureau Veritas (BV)
Registro Italiano Navale (RINA)
Det Norske Veritas (DNV)
Russian Maritime Register of Shipping (RMRS)
American Bureau of Shipping (ABS)
Nippon Kaiji Kyokai (NKK)
CCC (China)
KC (Korea)
JIS (Japan)
GOST/EAC (Russia)
CSA C22.2
EC directive "Low Voltage Directive" (LVD) no. 2014/35/EC
EC directive "Electromagnetic Compatibility Directive" (EMC) 2014/30/EC
Lloyd's Register of Shipping (LR)
Germanischer Lloyd (GL)
Bureau Veritas (BV)
Registro Italiano Navale (RINA)
Det Norske Veritas (DNV)
Russian Maritime Register of Shipping (RMRS)
American Bureau of Shipping (ABS)
Nippon Kaiji Kyokai (NKK)
CCC (China)
KC (Korea)
JIS (Japan)
GOST/EAC (Russia)
Benefits
Maximum flexibility for every application - SACE Tmax XT sets standards for electrical installations.
- Easy selection -- one-fits-all accessories and intuitive design pave the way for fast upgrades and create values through the entire customer journey even for the most critical projects.
Ease of selection
- The clever organization of the SACE Tmax XT range and the user-friendly software e-Configure allows the customer to easily select and customize the right products for their needs.
One-fits-all accessories
- Improving the circuit breaker from its basic functions to a more versatile and sophisticated device is made possible thanks to the SACE Tmax XT modular structure and the variety of available accessories.
Upgradability
- The Ekip Touch and Hi-Touch trip units can always be upgraded via ABB Ability MarketplaceTM and new functionalities shall be always available for an ever ending future.
Continuity of service and equipment protection
- SACE Tmax XT sets standards when extreme breaking capacity is needed.
- Sharing the same logics interfaces and features regardless of operating voltage environmental conditions. Embedding the most advanced protections into the smallest of frames.
Electrical performance
- SACE Tmax XT is designed and tested to meet any installation requirement even the most critical ones.
Metering
- SACE Tmax XT provides all the tools needed to set up a competent and effective energy management strategy thanks to the trip units able to measure electrical parameters with 1% accuracy certification.
Protections and logics
- SACE Tmax XT integrates extra functionalities into the size of a standard molded case circuit breaker.
- The most advanced protection functions and logics are available thanks to its cutting-edge trip units.
- Easy selection -- one-fits-all accessories and intuitive design pave the way for fast upgrades and create values through the entire customer journey even for the most critical projects.
Ease of selection
- The clever organization of the SACE Tmax XT range and the user-friendly software e-Configure allows the customer to easily select and customize the right products for their needs.
One-fits-all accessories
- Improving the circuit breaker from its basic functions to a more versatile and sophisticated device is made possible thanks to the SACE Tmax XT modular structure and the variety of available accessories.
Upgradability
- The Ekip Touch and Hi-Touch trip units can always be upgraded via ABB Ability MarketplaceTM and new functionalities shall be always available for an ever ending future.
Continuity of service and equipment protection
- SACE Tmax XT sets standards when extreme breaking capacity is needed.
- Sharing the same logics interfaces and features regardless of operating voltage environmental conditions. Embedding the most advanced protections into the smallest of frames.
Electrical performance
- SACE Tmax XT is designed and tested to meet any installation requirement even the most critical ones.
Metering
- SACE Tmax XT provides all the tools needed to set up a competent and effective energy management strategy thanks to the trip units able to measure electrical parameters with 1% accuracy certification.
Protections and logics
- SACE Tmax XT integrates extra functionalities into the size of a standard molded case circuit breaker.
- The most advanced protection functions and logics are available thanks to its cutting-edge trip units.
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - Tmax XT UL-CSA - Catalogue (2021).pdf | 02 Feb 2023 | English (US) |