1SDA080219R1XT4N 250 EKIP E-LSIG In=40A 4p FF UL/CSA (XT4NU4040HFF000XXX)
XT4N 250 EKIP E-LSIG In=40A 4p FF UL/CSA (XT4NU4040HFF000XXX)
Moulded Case Circuit Breaker (MCCB) - ABB / SACE (Tmax XT (UL/CSA) series) - XT4N 250 EKIP E-LSIG In=40A 4p FF UL/CSA (XT4NU4040HFF000XXX) - 4-poles (4P4d) - Rated current 40A - Short circuit rating 18kA (600Vac; UL489) - Electronic (Ekip E-LSIG) trip unit - Rated voltage 600Vac - equivalent to XT4N 250 EKIPE-LSIGIN=40A4PFFUL/CSA / XT4N250EKIPELSIGIn40A4pFFULCSA
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
1SDA080219R1
Online Price
$6,868.45
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
1SDA080219R1ABB - Tmax XT UL/CSA
Description
Moulded Case Circuit Breaker (MCCB) - ABB / SACE (Tmax XT (UL/CSA) series) - XT4N 250 EKIP E-LSIG In=40A 4p FF UL/CSA (XT4NU4040HFF000XXX) - 4-poles (4P4d) - Rated current 40A - Short circuit rating 18kA (600Vac; UL489) - Electronic (Ekip E-LSIG) trip unit - Rated voltage 600Vac - equivalent to XT4N 250 EKIPE-LSIGIN=40A4PFFUL/CSA / XT4N250EKIPELSIGIn40A4pFFULCSA
Specifications
Primary brand
ABB
Secondary brand
SACE
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
Tmax XT (UL/CSA)
Sub-range name
XT4N
Functions
Moulded Case Circuit Breaker (MCCB)
L pre-alarm and alarm LED
L alarm output contact
Circuit-breaker status (open/closed) (signalling via Modbus)
Mode (local/remote) (signalling via Modbus)
Protection parameters set (signalling via Modbus)
Protections (L / S / I / G) (signalling via Modbus)
Failed tripping under fault conditions (signalling via Modbus)
Record of last trip data
Alarm reset via Modbus
Circuit-breaker reset (with motor operator) via Modbus
Setting the curves and protection thresholds via Modbus
Changes in circuit-breaker state / protections / alarms (signalling via Modbus)
L pre-alarm and alarm LED
L alarm output contact
Circuit-breaker status (open/closed) (signalling via Modbus)
Mode (local/remote) (signalling via Modbus)
Protection parameters set (signalling via Modbus)
Protections (L / S / I / G) (signalling via Modbus)
Failed tripping under fault conditions (signalling via Modbus)
Record of last trip data
Alarm reset via Modbus
Circuit-breaker reset (with motor operator) via Modbus
Setting the curves and protection thresholds via Modbus
Changes in circuit-breaker state / protections / alarms (signalling via Modbus)
Poles
4-poles (4P4d)
Rated current
40A
Trip current rating
40 AT
Frame current rating
250 AF
Rated Voltage (DC)
500Vdc
Rated voltage (AC)
600Vac
Rated impulse voltage (Uimp)
8 kV
Connection type
Ring-lug or bar connections
Short circuit breaking rating
65kA (240Vac; UL489)
25kA (480Vac; UL489)
18kA (600Vac; UL489)
25kA (480Vac; UL489)
18kA (600Vac; UL489)
Trip unit type
Electronic
Ekip E-LSIG
Ekip E-LSIG
Protection functions
(L) Protection against overload
(S) Protection against short-circuit with time delay
(I) Instantaneous protection against short-circuit
(G) Protection against earth fault
(S) Protection against short-circuit with time delay
(I) Instantaneous protection against short-circuit
(G) Protection against earth fault
Protection settings
L - Protection against overload -- adjustable 0.18...1 x In (7.2A...40A)
S - Protection against short-circuit with time delay -- adjustable 0.6...10 x In (24A...400A); with adjustable time trip curve
I - Instantaneous protection against short-circuit -- adjustable from 1.5 - 15 x In (60A...600A)
G - Protection against earth fault -- adjustable 0.2...1 x In; 0.1...0.8s
S - Protection against short-circuit with time delay -- adjustable 0.6...10 x In (24A...400A); with adjustable time trip curve
I - Instantaneous protection against short-circuit -- adjustable from 1.5 - 15 x In (60A...600A)
G - Protection against earth fault -- adjustable 0.2...1 x In; 0.1...0.8s
Measurement function
Phase current (I1/I2/I3/IN)
Phase current minimum value
Phase current maximum value
Ground current (Ig)
Phase voltage runtime/max/min (V1N/V2N/V3N) (4P breakers with neutral connected)
Line voltage runtime/max/min (U12/U23/U31)
Phase power runtime/max/min (P1/P2/P3) (4P breakers with neutral connected)
Total power runtime/max/min
Phase power runtime/max/min (Q1/Q2/Q3) (4P breakers with neutral connected)
Total power runtime/max/min
Phase power runtime/max/min (S1/S2/S3) (4P breakers with neutral connected)
Total power runtime/max/min
Total energy
Incoming energy
Outgoing energy
Total energy
Incoming energy
Outgoing energy
Total energy
Harmonic analisys (Available on request by sending a Modbus command)
THD of phase L1/L2/L3 (Available on request by sending a Modbus command)
Frequency runtime/max/min
PF of phase L1/L2/L3 (4P breakers with neutral connected)
Total number of operations
Total number of trips
Number of trip tests
Number of manual operations
Number of trips for each individual protection function
Phase current minimum value
Phase current maximum value
Ground current (Ig)
Phase voltage runtime/max/min (V1N/V2N/V3N) (4P breakers with neutral connected)
Line voltage runtime/max/min (U12/U23/U31)
Phase power runtime/max/min (P1/P2/P3) (4P breakers with neutral connected)
Total power runtime/max/min
Phase power runtime/max/min (Q1/Q2/Q3) (4P breakers with neutral connected)
Total power runtime/max/min
Phase power runtime/max/min (S1/S2/S3) (4P breakers with neutral connected)
Total power runtime/max/min
Total energy
Incoming energy
Outgoing energy
Total energy
Incoming energy
Outgoing energy
Total energy
Harmonic analisys (Available on request by sending a Modbus command)
THD of phase L1/L2/L3 (Available on request by sending a Modbus command)
Frequency runtime/max/min
PF of phase L1/L2/L3 (4P breakers with neutral connected)
Total number of operations
Total number of trips
Number of trip tests
Number of manual operations
Number of trips for each individual protection function
Operating mode
Toggle
Electrical durability (with load)
8000 operations
Mechanical durability (at no load)
25 000 operations
Order code / Manufacturer SKU
XT4N 250 EKIP E-LSIG In=40A 4p FF UL/CSA
XT4NU4040HFF000XXX
XT4NU4040HFF000XXX
Manufacturer product status
Commercialized
Equivalent to
XT4N 250 EKIPE-LSIGIN=40A4PFFUL/CSA
XT4N250EKIPELSIGIn40A4pFFULCSA
XT4N250EKIPELSIGIn40A4pFFULCSA
EAN code
8015644867485
UPC code
888614411616
UNSPSC code
39121616
Compliant with standard(s)
UL 489
CSA C22.2
CSA C22.2
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - SACE Tmax XT UL-CSA - Catalogue.pdf | 18 May 2021 | English (US) |
ABB - SACE Tmax XT UL-CSA - Technical characteristics.pdf | 18 May 2021 | English (US) |