Pilz
PILZ-774595PZE X5 24Vdc 5N/O
PZE X5 24Vdc 5N/O
Single or dual-channel safety relay contact expansion module - SIL3 / PL.e / Cat.4 - Pilz (PNOZ X PZE X5) - PZE X5 24Vdc 5N/O - 20.4-26.4Vdc (24Vdc nom.) supp. voltage - 2 x digital inputs (24Vdc; 35mA) + 5 x instantaneous safety outputs (5NO / 5xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34; 43-44; 53-54) - fixed screw term. connections - DIN rail mounting (W45mm) - IP40 - rated for -10...+55°C ambient
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PILZ-774595
Online Price
$364.14
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Pilz - PNOZ X / PZE X5PILZ-774595
Description
Single or dual-channel safety relay contact expansion module - SIL3 / PL.e / Cat.4 - Pilz (PNOZ X PZE X5) - PZE X5 24Vdc 5N/O - 20.4-26.4Vdc (24Vdc nom.) supp. voltage - 2 x digital inputs (24Vdc; 35mA) + 5 x instantaneous safety outputs (5NO / 5xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34; 43-44; 53-54) - fixed screw term. connections - DIN rail mounting (W45mm) - IP40 - rated for -10...+55°C ambient
Specifications
Primary brand
Pilz
Main function
Safety relay
Product series / family name
PNOZ X
Sub-range name
PZE X5
Functions
Single or dual-channel safety relay contact expansion module
Instantaneous contact expansion
Instantaneous contact expansion
Supply voltage (DC)
20.4-26.4Vdc (24Vdc nom.)
Display
Power LED indicator
CH.1 LED indicator
CH.2 LED indicator
CH.1 LED indicator
CH.2 LED indicator
Rated current
Safety output contacts ratings
8A (24Vdc; DC-1)
8A (240Vac; AC-1)
7A (24Vdc; DC-13)
5A (230Vac; AC-15)
8A (24Vdc; DC-1)
8A (240Vac; AC-1)
7A (24Vdc; DC-13)
5A (230Vac; AC-15)
Connection type
fixed screw term. connections
Protection functions
2 operating modes (with or without detection of shorts across contacts)
Net Height (mm)
87 mm
Net Width (mm)
45 mm
Net Depth (mm)
121 mm
Mounting mode
DIN rail mounting
Operating mode
Single-channel / Dual-channel -- with / without detection of shorts across contacts
Digital inputs
2 x digital inputs (24Vdc; 35mA)
1 x feedback loop input (SPST with 2NC contacts in series) (Y1-Y2)
1 x feedback loop input (SPST with 2NC contacts in series) (Y1-Y2)
Digital outputs
5 x instantaneous safety outputs (5NO / 5xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34; 43-44; 53-54)
Degree of protection
IP40
Dimensions
W45mm
Material
PPO housing
ABS front housing
ABS front housing
Ambient air temperature for operation
-10...+55 °C
Power consumption
3.5 W
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL3 / PL.e / Cat.4
PFH = 2.31E-09
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL3 / PL.e / Cat.4
PFH = 2.31E-09
Class
SIL3 / PL.e / Cat.4
Benefits
Positive-guided relay outputs -- 5 safety contacts (N/O); instantaneous
LED display for supply voltage and switch status of the safety contacts
Connection for feedback loop
Operation -- Single or Dual-channel
The contact expansion module expands an existing circuit.
As the output relays are monitored via the base unit's feedback loop; the safety functions on the existing circuit are transferred to the contact expansion module.
The safety function remains effective in the case of a component failure.
Earth fault in the feedback loop -- Detected; depending on the base unit that is used.
Earth fault in the input circuit -- The output relays de-energize and the safety contacts open.
LED display for supply voltage and switch status of the safety contacts
Connection for feedback loop
Operation -- Single or Dual-channel
The contact expansion module expands an existing circuit.
As the output relays are monitored via the base unit's feedback loop; the safety functions on the existing circuit are transferred to the contact expansion module.
The safety function remains effective in the case of a component failure.
Earth fault in the feedback loop -- Detected; depending on the base unit that is used.
Earth fault in the input circuit -- The output relays de-energize and the safety contacts open.