Pilz
PILZ-777314PNOZ X3.10P 24VacDC 3N/O 1N/C 1so
PNOZ X3.10P 24VacDC 3N/O 1N/C 1so
Single or dual-channel safety relay - SIL3 / PL.e / Cat.4 - Pilz (PNOZ X PNOZ X3.10P) - PNOZ X3.10P 24VacDC 3N/O 1N/C 1so - 20.4-26.4Vdc (24Vdc nom.) / 20.4-26.4Vac (24Vac nom.) supp. voltage - 2 x digital inputs (24Vdc; 40mA) (S11-S12; S21-S22; S31-S32) + 3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34) + 1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in parallel) (41-42) + 1 x aux. output (semiconductor output (1SO); 24Vdc; 20mA) (Y32) - plug-in/detachable screw term. connections - DIN rail mounting (W45mm) - IP40 - rated for -20...+55°C ambient
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PILZ-777314
Online Price
$370.52
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Pilz - PNOZ X / PNOZ X3.10PPILZ-777314
Description
Single or dual-channel safety relay - SIL3 / PL.e / Cat.4 - Pilz (PNOZ X PNOZ X3.10P) - PNOZ X3.10P 24VacDC 3N/O 1N/C 1so - 20.4-26.4Vdc (24Vdc nom.) / 20.4-26.4Vac (24Vac nom.) supp. voltage - 2 x digital inputs (24Vdc; 40mA) (S11-S12; S21-S22; S31-S32) + 3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34) + 1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in parallel) (41-42) + 1 x aux. output (semiconductor output (1SO); 24Vdc; 20mA) (Y32) - plug-in/detachable screw term. connections - DIN rail mounting (W45mm) - IP40 - rated for -20...+55°C ambient
Specifications
Primary brand
Pilz
Main function
Safety relay
Product series / family name
PNOZ X
Sub-range name
PNOZ X3.10P
Functions
Single or dual-channel safety relay
Safety gate monitoring
Instantaneous E-STOP (Emergency stop) monitoring
Limit switch monitoring
Light beam device monitoring type 2 (with or without test pulse) & type 4
Monitored manual reset
Safety gate monitoring
Instantaneous E-STOP (Emergency stop) monitoring
Limit switch monitoring
Light beam device monitoring type 2 (with or without test pulse) & type 4
Monitored manual reset
Supply voltage (AC)
20.4-26.4Vac (24Vac nom.)
Supply voltage (DC)
20.4-26.4Vdc (24Vdc nom.)
Display
Power LED indicator
CH.1 LED indicator
CH.2 LED indicator
CH.1 LED indicator
CH.2 LED indicator
Rated current
Safety output contacts ratings
8A (24Vdc; DC-1)
8A (240Vac; AC-1)
6A (24Vdc; DC-13)
5A (230Vac; AC-15)
8A (24Vdc; DC-1)
8A (240Vac; AC-1)
6A (24Vdc; DC-13)
5A (230Vac; AC-15)
Connection type
plug-in/detachable screw term. connections
Protection functions
2 operating modes (with or without detection of shorts across contacts)
Net Height (mm)
94 mm
Net Width (mm)
45 mm
Net Depth (mm)
121 mm
Mounting mode
DIN rail mounting
Operating mode
Single-channel operation -- No redundancy in the input circuit -- earth faults in the start and input circuit are detected.
Dual-channel operation -- with detection of shorts across contacts / Redundant input circuit -- detects earth faults in the start and input circuit; short circuits in the input circuit; shorts across contacts in the input circuit.
Automatic start -- Unit is active once the input circuit has been closed.
Manual start -- Unit is active once the input circuit and the start circuit are closed.
Monitored start -- Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed
Increase in the number of available contacts by connecting contact expansion modules or external contactors/relays.
Dual-channel operation -- with detection of shorts across contacts / Redundant input circuit -- detects earth faults in the start and input circuit; short circuits in the input circuit; shorts across contacts in the input circuit.
Automatic start -- Unit is active once the input circuit has been closed.
Manual start -- Unit is active once the input circuit and the start circuit are closed.
Monitored start -- Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed
Increase in the number of available contacts by connecting contact expansion modules or external contactors/relays.
Digital inputs
2 x digital inputs (24Vdc; 40mA) (S11-S12; S21-S22; S31-S32)
1 x start input (S13-S16; S33-S34)
1 x start input (S13-S16; S33-S34)
Digital outputs
3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34)
1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in parallel) (41-42)
1 x aux. output (semiconductor output (1SO); 24Vdc; 20mA) (Y32)
1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in parallel) (41-42)
1 x aux. output (semiconductor output (1SO); 24Vdc; 20mA) (Y32)
Degree of protection
IP40
Dimensions
W45mm
Material
PPO housing
ABS front housing
ABS front housing
Ambient air temperature for operation
-20...+55 °C
Power consumption
2.5 W
Power consumption
5 VA
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 60947-5-1
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL3 / PL.e / Cat.4
PFH = 2.31E-09
CE
cULus
EAC
TUV
CCC
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL3 / PL.e / Cat.4
PFH = 2.31E-09
CE
cULus
EAC
TUV
CCC
Class
SIL3 / PL.e / Cat.4
Benefits
Positive-guided relay outputs -- 3 safety contacts (N/O); instantaneous / 1 auxiliary contact (N/C); instantaneous
1 semiconductor output
Connection options for E-STOP pushbutton / Safety gate limit switch / Start button
LED display for Supply voltage / Switch state of the safety contacts / Input circuit
Semiconductor output signals -- Switch state of the safety contacts
The circuit is redundant with built-in self-monitoring.
The safety function remains effective in the case of a component failure.
The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
1 semiconductor output
Connection options for E-STOP pushbutton / Safety gate limit switch / Start button
LED display for Supply voltage / Switch state of the safety contacts / Input circuit
Semiconductor output signals -- Switch state of the safety contacts
The circuit is redundant with built-in self-monitoring.
The safety function remains effective in the case of a component failure.
The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.