Pilz
PILZ-784138PNOZ e3vp C 300/24Vdc 1so 1so t
PNOZ e3vp C 300/24Vdc 1so 1so t
Single or dual-channel safety relay - SIL3 / PL.e / Cat.4 - Pilz (PNOZelog PNOZ e3vp) - PNOZ e3vp C 300/24Vdc 1so 1so t - 19.2-30Vdc (24Vdc nom.) supp. voltage - 2A rated current - 1 x digital input (24Vdc; 5mA) (S12; S24; Y4) + 2 x logic inputs (AND-S36; OR-S35) + 1 x instantaneous aux. output (semiconductor output (1SO)) (Y32) + 1 x instantaneous safety output (semiconductor output (1SO)) (14) + 1 x delayed safety output (semiconductor output (1SO); 0-300s time-delay selectable 0s / 15s / 25s / 50s / 100s / 150s / 200s / 250s / 300s) (24) + 2 x test pulse outputs (S11-S23) - plug-in/detachable spring term. connections - DIN rail mounting (W22.5mm) - IP40 - rated for -10...+55°C ambient
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PILZ-784138
Online Price
$414.93
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Pilz - PNOZelog / PNOZ e3vpPILZ-784138
Description
Single or dual-channel safety relay - SIL3 / PL.e / Cat.4 - Pilz (PNOZelog PNOZ e3vp) - PNOZ e3vp C 300/24Vdc 1so 1so t - 19.2-30Vdc (24Vdc nom.) supp. voltage - 2A rated current - 1 x digital input (24Vdc; 5mA) (S12; S24; Y4) + 2 x logic inputs (AND-S36; OR-S35) + 1 x instantaneous aux. output (semiconductor output (1SO)) (Y32) + 1 x instantaneous safety output (semiconductor output (1SO)) (14) + 1 x delayed safety output (semiconductor output (1SO); 0-300s time-delay selectable 0s / 15s / 25s / 50s / 100s / 150s / 200s / 250s / 300s) (24) + 2 x test pulse outputs (S11-S23) - plug-in/detachable spring term. connections - DIN rail mounting (W22.5mm) - IP40 - rated for -10...+55°C ambient
Specifications
Primary brand
Pilz
Main function
Safety relay
Product series / family name
PNOZelog
Sub-range name
PNOZ e3vp
Functions
Single or dual-channel safety relay
Safety gate monitoring
Mechanical safety gate monitoring
Non-contact safety gate monitoring
ON-delay de-energization timer
Monitored manual reset
Start-up testing
with AND input
with OR input
Self-test
Safety gate monitoring
Mechanical safety gate monitoring
Non-contact safety gate monitoring
ON-delay de-energization timer
Monitored manual reset
Start-up testing
with AND input
with OR input
Self-test
Supply voltage (DC)
19.2-30Vdc (24Vdc nom.)
Display
Power LED indicator
CH.1 LED indicator
CH.2 LED indicator
CH.1 LED indicator
CH.2 LED indicator
Rated current
2A
Connection type
plug-in/detachable spring term. connections
Protection functions
2 operating modes (with or without detection of shorts across contacts)
Net Height (mm)
101 mm
Net Width (mm)
22.5 mm
Net Depth (mm)
121 mm
Mounting mode
DIN rail mounting
Operating mode
Dual-channel operation -- Earth faults in the input circuit and shorts between the input circuit contacts will be detected.
Automatic start -- Unit becomes active once the contact at S12 has been closed and the contact at S24 has been opened in the input circuit.
Monitored start -- Unit is not active until the start button has been operated and then released.
The start-up test prevents automatic restarting after a power failure and subsequent return of voltage. The unit checks whether safety gates that are closed have been opened and then closed again when supply voltage is applied.
Increase in the number of available contacts by connecting contact expansion modules or external contactors/relays.
Automatic start -- Unit becomes active once the contact at S12 has been closed and the contact at S24 has been opened in the input circuit.
Monitored start -- Unit is not active until the start button has been operated and then released.
The start-up test prevents automatic restarting after a power failure and subsequent return of voltage. The unit checks whether safety gates that are closed have been opened and then closed again when supply voltage is applied.
Increase in the number of available contacts by connecting contact expansion modules or external contactors/relays.
Digital inputs
1 x digital input (24Vdc; 5mA) (S12; S24; Y4)
2 x logic inputs (AND-S36; OR-S35)
1 x feedback input (Y6-Y7)
1 x start input (S34)
1 x self-monitoring input (Y5)
2 x logic inputs (AND-S36; OR-S35)
1 x feedback input (Y6-Y7)
1 x start input (S34)
1 x self-monitoring input (Y5)
Digital outputs
1 x instantaneous aux. output (semiconductor output (1SO)) (Y32)
1 x instantaneous safety output (semiconductor output (1SO)) (14)
1 x delayed safety output (semiconductor output (1SO); 0-300s time-delay selectable 0s / 15s / 25s / 50s / 100s / 150s / 200s / 250s / 300s) (24)
2 x test pulse outputs (S11-S23)
1 x instantaneous safety output (semiconductor output (1SO)) (14)
1 x delayed safety output (semiconductor output (1SO); 0-300s time-delay selectable 0s / 15s / 25s / 50s / 100s / 150s / 200s / 250s / 300s) (24)
2 x test pulse outputs (S11-S23)
Degree of protection
IP40
Dimensions
W22.5mm
Material
PPO housing
ABS front housing
ABS front housing
Ambient air temperature for operation
-10...+55 °C
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 60947-5-1
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL3 / PL.e / Cat.4 (SC output via logic input; SC output via 2-ch. input circuit)
PFH = 3.61E-09 (SC output via logic input)
PFH = 3.44E-09 (SC output via 2-ch. input circuit)
EN 60947-5-3
CE
cULus
EAC
TUV
CCC
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL3 / PL.e / Cat.4 (SC output via logic input; SC output via 2-ch. input circuit)
PFH = 3.61E-09 (SC output via logic input)
PFH = 3.44E-09 (SC output via 2-ch. input circuit)
EN 60947-5-3
CE
cULus
EAC
TUV
CCC
Class
SIL3 / PL.e / Cat.4
Benefits
Outputs using semiconductor technology -- 1 safety output; either instantaneous or delayed / 1 safety output; delayed / 1 auxiliary output / 2 test pulse outputs
Connection options -- Safety sensors PSEN 2.1p-10 and PSEN 2.1p-11 / Position switch with N/C / N/O combination
LED display for supply voltage / switch state of safety outputs
2 logic inputs (AND/OR) for logic connections between several units
Feedback loop for monitoring external contactors
Detection of shorts across contacts via test pulse outputs
The circuit is redundant with built-in self-monitoring.
The safety device remains effective in the case of a component failure.
The safety outputs are tested periodically using an off-test.
Connection options -- Safety sensors PSEN 2.1p-10 and PSEN 2.1p-11 / Position switch with N/C / N/O combination
LED display for supply voltage / switch state of safety outputs
2 logic inputs (AND/OR) for logic connections between several units
Feedback loop for monitoring external contactors
Detection of shorts across contacts via test pulse outputs
The circuit is redundant with built-in self-monitoring.
The safety device remains effective in the case of a component failure.
The safety outputs are tested periodically using an off-test.
Related Documents
Name | Last Update | Language |
---|---|---|
Pilz - PNOZ e3vp - Manual.pdf | 14 Oct 2021 | English (US) |