PULS
YR40.482
Dual-input redundancy module (2 x inputs + 1 x output) with built-in decoupl. MOSFET (for 1+1 or N+1 redundancy) + ATEX approval - PULS (DIMENSION Y-series) - 24-56Vdc (24Vdc / 48Vdc nom.) / 40A output - with screw-clamp connections - DIN rail mounting (46mm width) - equivalent to #YR40482
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
YR40.482
Online Price
$260.00
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
YR40.482
Description
Dual-input redundancy module (2 x inputs + 1 x output) with built-in decoupl. MOSFET (for 1+1 or N+1 redundancy) + ATEX approval - PULS (DIMENSION Y-series) - 24-56Vdc (24Vdc / 48Vdc nom.) / 40A output - with screw-clamp connections - DIN rail mounting (46mm width) - equivalent to #YR40482
Specifications
Primary brand
PULS
Main function
Redundancy unit
Product series / family name
DIMENSION series
Sub-range name
Y-series
Functions
Dual-input redundancy module (2 x inputs + 1 x output)
Design
built-in decoupl. MOSFET (for 1+1 or N+1 redundancy)
ATEX approval
ATEX approval
Supply voltage (DC)
20.4Vdc-64.4Vdc (24Vdc / 48Vdc / 60Vdc nom.)
Rated current
40A (at 56Vdc)
1A/+60°C...+70°C (derating)
1A/+60°C...+70°C (derating)
Output voltage (DC)
24-56Vdc (24Vdc / 48Vdc nom.)
Connection type
screw-clamp connections
Protection functions
short-circuit protection (45A threshold at 6V)
Series / parallel operation -- 1+1 Redundancy Use of 2 identical power supplies in parallel to provide continued operation following most failures in a single power supply. The 2 power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements. N+1 Redundancy Use of 3 or more identical power supplies in parallel to provide continued operation following most failures in a single power supply. All power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements.
Series / parallel operation -- 1+1 Redundancy Use of 2 identical power supplies in parallel to provide continued operation following most failures in a single power supply. The 2 power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements. N+1 Redundancy Use of 3 or more identical power supplies in parallel to provide continued operation following most failures in a single power supply. All power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements.
Net Width (mm)
46 mm
Mounting mode
DIN rail mounting
Dimensions
W46mm x H124mm x D127mm
Ambient air temperature for operation
-40...+70 °C
Current consumption
1000A peak max. inrush (at 20.4-64.4Vdc input)
Technical compatibility with
Suitable for all DIMENSION Power Supplies
Power dissipation/losses
(20.4-64.4Vdc input; 2x10A input) 1.8 W
(20.4-64.4Vdc input; 20A input) 2.3 W
(20.4-64.4Vdc input; 20A input) 2.3 W
Manufacturer product status
Commercialized
Equivalent to
YR40482
Capacitance
(output stage) 310 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
Benefits
For N+1 and 1+1 redundant systems
Dual input with single output
Suitable for all DIMENSION Power Supplies
Only 60mV Voltage Drop at 20A Output Current
Only 1.8W Loss at 20A and 5.4W at 40A Output Current
160% (65A) peak load capability
Reverse input polarity protection
Full power between -40°C and +60°C
Width only 46mm
Rugged metal housing
Easy wiring;
Distribution terminal for negative pole included
3 Year warranty
The YR40.482 is a redundancy module which can be used to build 1+1 and N+1 redundant system. It is equipped with 2 input channels which can be connected to power supplies with up to 20A output current and 1 output which can carry nominal currents up to 40A. The novelty of this redundancy module is the utilization of mosfets instead of diodes for the decoupling of the 2 input channels. This reduces the heat generation and the voltage drop between input and output. The redundancy module does not require an additional auxiliary voltage. Due to the low power losses the unit is very slender and only requires 46mm width on the DIN-rail. Large connection terminals allow for a safe and fast installation. The large international approval package makes this unit suitable for nearly every application.
Dual input with single output
Suitable for all DIMENSION Power Supplies
Only 60mV Voltage Drop at 20A Output Current
Only 1.8W Loss at 20A and 5.4W at 40A Output Current
160% (65A) peak load capability
Reverse input polarity protection
Full power between -40°C and +60°C
Width only 46mm
Rugged metal housing
Easy wiring;
Distribution terminal for negative pole included
3 Year warranty
The YR40.482 is a redundancy module which can be used to build 1+1 and N+1 redundant system. It is equipped with 2 input channels which can be connected to power supplies with up to 20A output current and 1 output which can carry nominal currents up to 40A. The novelty of this redundancy module is the utilization of mosfets instead of diodes for the decoupling of the 2 input channels. This reduces the heat generation and the voltage drop between input and output. The redundancy module does not require an additional auxiliary voltage. Due to the low power losses the unit is very slender and only requires 46mm width on the DIN-rail. Large connection terminals allow for a safe and fast installation. The large international approval package makes this unit suitable for nearly every application.
Electrical durability
(at 40°C; 20A output; 2x10A input) 448000 hours
(at 40°C; 40A output; 2x20A input) 222000 hours
(at 25°C; 20A output; 2x10A input) 1267000 hours
(at 25°C; 40A output; 2x20A input) 629000 hours
(at 40°C; 40A output; 2x20A input) 222000 hours
(at 25°C; 20A output; 2x10A input) 1267000 hours
(at 25°C; 40A output; 2x20A input) 629000 hours
Ripple
60mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
6656000h (at 40°C; 2x10A input; MTBF SN 29500 IEC 61709)
4098000h (at 40°C; 2x20A input; MTBF SN 29500 IEC 61709)
11990000h (at 25°C; 2x10A input; MTBF SN 29500 IEC 61709)
7808000h (at 25°C; 2x20A input; MTBF SN 29500 IEC 61709)
211000h (at 40°C; 2x10A input; MTBF MIL HDBK 217F GB40)
178000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GB40)
288000h (at 25°C; 2x10A input; MTBF MIL HDBK 217F GB25)
238000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GB25)
959000h (at 40°C; 2x10A input; MTBF MIL HDBK 217F GF40)
839000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GF40)
1332000h (at 25°C; 2x10A input; MTBF MIL HDBK 217F GF25)
1144000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GF25)
4098000h (at 40°C; 2x20A input; MTBF SN 29500 IEC 61709)
11990000h (at 25°C; 2x10A input; MTBF SN 29500 IEC 61709)
7808000h (at 25°C; 2x20A input; MTBF SN 29500 IEC 61709)
211000h (at 40°C; 2x10A input; MTBF MIL HDBK 217F GB40)
178000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GB40)
288000h (at 25°C; 2x10A input; MTBF MIL HDBK 217F GB25)
238000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GB25)
959000h (at 40°C; 2x10A input; MTBF MIL HDBK 217F GF40)
839000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GF40)
1332000h (at 25°C; 2x10A input; MTBF MIL HDBK 217F GF25)
1144000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GF25)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - YR40-482-1 - Datasheet.pdf | 01 Oct 2021 | English (US) |