PULS
YR80.242
Dual-input redundancy module (2 x inputs + 1 x output) with built-in decoupl. MOSFET (for 1+1 or N+1 redundancy) + ATEX approval - PULS (DIMENSION Y-series) - 12-28Vdc (12Vdc / 24Vdc nom.) / 80A output - with screw-clamp connections - DIN rail mounting (46mm width) - equivalent to #YR80242
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
YR80.242
Online Price
$275.00
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
YR80.242
Description
Dual-input redundancy module (2 x inputs + 1 x output) with built-in decoupl. MOSFET (for 1+1 or N+1 redundancy) + ATEX approval - PULS (DIMENSION Y-series) - 12-28Vdc (12Vdc / 24Vdc nom.) / 80A output - with screw-clamp connections - DIN rail mounting (46mm width) - equivalent to #YR80242
Specifications
Primary brand
PULS
Main function
Redundancy unit
Product series / family name
DIMENSION series
Sub-range name
Y-series
Functions
Dual-input redundancy module (2 x inputs + 1 x output)
Design
built-in decoupl. MOSFET (for 1+1 or N+1 redundancy)
ATEX approval
ATEX approval
Supply voltage (DC)
8.4Vdc-36.4Vdc (12Vdc / 24Vdc nom.)
Rated current
80A (at 28Vdc)
2A/+60°C...+70°C (derating)
2A/+60°C...+70°C (derating)
Output voltage (DC)
12-28Vdc (12Vdc / 24Vdc nom.)
Connection type
screw-clamp connections
Protection functions
short-circuit protection (44A threshold at 6V)
Series / parallel operation -- 1+1 Redundancy Use of 2 identical power supplies in parallel to provide continued operation following most failures in a single power supply. The 2 power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements. N+1 Redundancy Use of 3 or more identical power supplies in parallel to provide continued operation following most failures in a single power supply. All power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements.
Series / parallel operation -- 1+1 Redundancy Use of 2 identical power supplies in parallel to provide continued operation following most failures in a single power supply. The 2 power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements. N+1 Redundancy Use of 3 or more identical power supplies in parallel to provide continued operation following most failures in a single power supply. All power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements.
Net Width (mm)
46 mm
Mounting mode
DIN rail mounting
Dimensions
W46mm x H124mm x D127mm
Ambient air temperature for operation
-40...+70 °C
Current consumption
1500A peak max. inrush (at 8.4-36.4Vdc input)
Technical compatibility with
Suitable for all DIMENSION Power Supplies except QT40 Series
Power dissipation/losses
(8.4-36.4Vdc input; 2x20A input) 2.9 W
(8.4-36.4Vdc input; 40A input) 4.6 W
(8.4-36.4Vdc input; 40A input) 4.6 W
Manufacturer product status
Commercialized
Equivalent to
YR80242
Capacitance
(output stage) 320 μF
Compliant with standard(s)
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
IECEx
ATEX
Class I Div. 2 HazLoc
GL Marine
EAC Registration
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
Benefits
For N+1 and 1+1 redundant systems
Dual input with single output
Suitable for all DIMENSION Power Supplies except QT40 Series
Only 65mV Voltage Drop at 40A Output Current
Only 2.9W Loss at 40A and 11.8W at 80A Output Current
160% (130A) Peak Load Capability
Reverse input polarity protection
Full power between -40°C and +60°C
Width only 46mm
Rugged metal housing
Easy wiring;
Distribution terminal for negative pole included
3 Year warranty
The YR80.242 is a redundancy module which can be used to build 1+1 and N+1 redundant systems. It is equipped with 2 input channels which can be connected to power supplies with up to 40A output current and 1 output which can carry nominal currents up to 80A. In addition to the YR80.242 the YR80.241 is also available. This unit has an additional circuit included which generates a supply voltage for the internal mosfets even when the output of the unit is in a short circuit condition. This makes the unit suitable for any power supplies. The novelty of this redundancy module is the utilization of mosfets instead of diodes for the decoupling of the 2 input channels. This reduces the heat generation and the voltage drop between input and output. The redundancy module does not require an additional auxiliary voltage. Due to the low power losses the unit is very slender and only requires 46mm width on the DIN-rail. Large connection terminals allow for a safe and fast installation. The large international approval package makes this unit suitable for nearly every application.
Dual input with single output
Suitable for all DIMENSION Power Supplies except QT40 Series
Only 65mV Voltage Drop at 40A Output Current
Only 2.9W Loss at 40A and 11.8W at 80A Output Current
160% (130A) Peak Load Capability
Reverse input polarity protection
Full power between -40°C and +60°C
Width only 46mm
Rugged metal housing
Easy wiring;
Distribution terminal for negative pole included
3 Year warranty
The YR80.242 is a redundancy module which can be used to build 1+1 and N+1 redundant systems. It is equipped with 2 input channels which can be connected to power supplies with up to 40A output current and 1 output which can carry nominal currents up to 80A. In addition to the YR80.242 the YR80.241 is also available. This unit has an additional circuit included which generates a supply voltage for the internal mosfets even when the output of the unit is in a short circuit condition. This makes the unit suitable for any power supplies. The novelty of this redundancy module is the utilization of mosfets instead of diodes for the decoupling of the 2 input channels. This reduces the heat generation and the voltage drop between input and output. The redundancy module does not require an additional auxiliary voltage. Due to the low power losses the unit is very slender and only requires 46mm width on the DIN-rail. Large connection terminals allow for a safe and fast installation. The large international approval package makes this unit suitable for nearly every application.
Electrical durability
(at 40°C; 40A output; 2x20A input) 499000 hours
(at 40°C; 40A output; 2x40A input) 85000 hours
(at 25°C; 80A output; 2x20A input) 1410000 hours
(at 25°C; 80A output; 2x40A input) 239000 hours
(at 40°C; 40A output; 2x40A input) 85000 hours
(at 25°C; 80A output; 2x20A input) 1410000 hours
(at 25°C; 80A output; 2x40A input) 239000 hours
Ripple
65mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
6020000h (at 40°C; 2x20A input; MTBF SN 29500 IEC 61709)
2482000h (at 40°C; 2x40A input; MTBF SN 29500 IEC 61709)
10455000h (at 25°C; 2x20A input; MTBF SN 29500 IEC 61709)
4785000h (at 25°C; 2x40A input; MTBF SN 29500 IEC 61709)
179000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GB40)
133000h (at 40°C; 2x40A input; MTBF MIL HDBK 217F GB40)
239000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GB25)
173000h (at 25°C; 2x40A input; MTBF MIL HDBK 217F GB25)
949000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GF40)
724000h (at 40°C; 2x40A input; MTBF MIL HDBK 217F GF40)
1276000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GF25)
947000h (at 25°C; 2x40A input; MTBF MIL HDBK 217F GF25)
2482000h (at 40°C; 2x40A input; MTBF SN 29500 IEC 61709)
10455000h (at 25°C; 2x20A input; MTBF SN 29500 IEC 61709)
4785000h (at 25°C; 2x40A input; MTBF SN 29500 IEC 61709)
179000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GB40)
133000h (at 40°C; 2x40A input; MTBF MIL HDBK 217F GB40)
239000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GB25)
173000h (at 25°C; 2x40A input; MTBF MIL HDBK 217F GB25)
949000h (at 40°C; 2x20A input; MTBF MIL HDBK 217F GF40)
724000h (at 40°C; 2x40A input; MTBF MIL HDBK 217F GF40)
1276000h (at 25°C; 2x20A input; MTBF MIL HDBK 217F GF25)
947000h (at 25°C; 2x40A input; MTBF MIL HDBK 217F GF25)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - YR80-242-1 - Datasheet.pdf | 01 Oct 2021 | English (US) |